  Plot plan showing setup. If part of an overall event, this shall be supplied by the event coordinator.
  Notarized letter from property owner stating their approval.
  Proof of liability insurance.
  If tent is greater than 10’ x 10’, flame retardant certification is required. If multiple 10’ x 10’ tents are placed together to
create one large space under canopy, then a flame retardant certification shall be required on all tents.
  No smoking signs must be placed outside entrances.
  If there is to be wire fencing or chain link fencing, this fence shall be set back from the tent at least 5 feet and have at
least 2 exits.
  If tent has sides, the sides shall be in the up position unless there is inclement weather, than 2 sides must be in the up
position.
  Adjacent tents shall be spaced a minimum of five (5) feet to provide an area to be used as a means of emergency egress.
If stake lines are used to secure the tent, than the five (5) feet shall be measured from the stake line.
  The ground enclosed by any tent and ground not less than 120” outside the tent shall be cleared of all flammable or
combustible material or vegetation that is not used for necessary support equipment.
  If lighting is installed in tent, it shall be in the way that bulbs are not in direct contact with the tent. Bulb/lamp cages shall
be used.
  If power is supplied by generator, generator shall be a minimum of 5 feet from the tent and shall be isolated from contact
with the public by either physical guards, fencing, or an enclosure. Fuel containers shall not be stored within close
proximity of any ignition source.
  Any extension cords used shall be placed or positioned to not cause a trip/fall hazard.
  A minimum of one portable fire extinguisher with a rating of not less than 2-A:10-B:C shall be provided. (See note at
bottom)
  If an LP (propane) tank is used by the vendor it shall be positioned outside the footprint of the tent.
If cooking is involved:
Note: If Cooking is Involved:
  A minimum of one Class K portable fire extinguisher shall be provided for each concession stand that utilizes vegetable or
animal grease cooking oils or any other process that produces grease laden vapors. (See note at bottom.)
  Concession stands utilized for cooking shall have a minimum of 10 ft (3 m) of clearance on two sides and shall not be
located within 10 ft (3 m) of amusement rides or devices.
  If cooking is taking place under any tent, a flame retardant certification is required.
  Any appliance used for cooking that utilizes a vent, that appliance shall be positioned to vent outside the tent.
  Cooking equipment used in fixed, mobile, or temporary concessions, such as trucks, buses, trailers, pavilions, tents, or
any form of roofed enclosure, shall comply with this standard unless all or part of the installation is exempted by the AHJ.
(NFPA 1, Section 50.2.9)

 

 